🏠HVAC Load Lab v23 · linked to Install Assistant
Address first. Automatic weather research. Quick heating, sensible and latent estimates with transparent assumptions. Floor and room measurements are optional.
Property details & local weather
Automatically retrieved when you select an address. Unknown records remain unverified. Values are informational; verify on site.
Current conditions are not HVAC sizing conditions. Summer/winter figures are historical modeled proxies, not verified ASHRAE design temperatures.
Property measurements
Property records can suggest living area; confirm the actual conditioned area before calculating. You can also measure rooms below.
These are quick inputs, not buried in Advanced. Unverified defaults remain labeled in the report.
Home insulation
Choose the overall insulation condition. Default: average; confirm attic, walls, and floor conditions when possible.
System coverage
Whole-house load uses the conditioned floor area above.
Room measurements Optional
Add rooms in feet, choose First or Second floor, and record supply registers, duct material, and duct condition in each room. Floor totals update automatically; tap “Use room total” to populate the floor area above. For mini-splits, check only the rooms served and assign an indoor head/zone. Unconditioned adjacent spaces require additional design review.
Advanced options Customize assumptions
Window and exterior door measurement methods, plus detailed building assumptions. Automatic windows remain 20% of estimated exterior wall area.
Window calculation
Automatic uses 20% of estimated exterior wall area for regular windows. Glazed exterior doors are calculated separately. Select floor or room measurements to replace that assumption; measured entries are never added to the automatic estimate.
Automatic estimate selected. Actual glazing, shading, and orientation require site verification.
Exterior doors
Automatic mode assumes one insulated 3 Ă— 7 ft front door plus a configurable second door. A slider or French door adds its own glazing separately from regular windows. Measured doors can be assigned by floor or room; never enter the same glazed door as a window too.
Front door: one insulated 3 Ă— 7 ft door. Glass in the second door is added separately from the 20% regular-window estimate.
Door conduction is included in the heating and sensible cooling loads. Existing whole-house infiltration is not increased automatically.
These inputs are editable. Weather defaults use historical modeled data when available, not certified HVAC design conditions.
Floor-by-floor measurements (optional)
Automatically totaled from room measurements and each room’s Floor selection. These are planning allocations, not independent room-by-room Manual J loads.
Default 2 grains is a comparison assumption from the supplied EDS report, NOT independently verified local humidity. If you enter design outdoor RH, it overrides the grains assumption.
Room & floor cooling estimates
Preliminary allocations of the calculated load by measured room area. These are NOT independent room-by-room or floor-by-floor Manual J calculations. Exposure, windows, ceilings, adjacent spaces and duct losses can change actual loads.
Experimental simplified estimate (including moisture assumptions). Mini-split mode is a selected-area screening estimate, NOT a room-by-room load; heat transfer from adjacent unconditioned spaces is not fully modeled, not an ACCA Manual J, engineering design, or verified equipment sizing. Sensible and latent values use simplified moisture and airflow assumptions. Not a validated ACCA Manual J or verified Home Depot contract load report. Confirm design temperatures, humidity, infiltration, ventilation and construction; use an approved method for contract submission and final sizing.